Gali 15, 2016

13) Rentgeno spindulių spektrometrija – HVC kondensatorius, HV keraminis kondensatorius, skirtas kurti visų rūšių rentgeno aparatus.

13)X-ray Spectrometry–  HVC Capacitor, HV Ceramic Capacitor to build All kinds of X-ray machine. PARTICLE-INDUCED X-RAY EMISSION PIXE, using proton energies between 1 and 4 MeV, serves as an established method of nondestructive analysis in numerous application fields. Under these normal conditions, high-Z elements are usually detected via their L X-ray lines. In addition, the […]

Standartiniai Pranešimai
Gali 15, 2016

12) Rentgeno spindulių spektrometrija – HVC kondensatorius, HV keraminis kondensatorius, skirtas kurti visų rūšių rentgeno aparatus.

12)X-ray Spectrometry–  HVC Capacitor, HV Ceramic Capacitor to build All kinds of X-ray machine. For the purpose of light element analysis of microscopic particles, the samples are collected on conductive substrates and measured without conductive coating. The usually short measur- ing times for computer-controlled single-particle analysis help to avoid a large charge buildup on coarse […]

Standartiniai Pranešimai
Gali 15, 2016

11) Rentgeno spindulių spektrometrija – HVC kondensatorius, HV keraminis kondensatorius, skirtas kurti visų rūšių rentgeno aparatus.

11)X-ray Spectrometry–  HVC Capacitor, HV Ceramic Capacitor to build All kinds of X-ray machine. Since the TXRF is a well-accepted technique for analysis o ultrapure materials and very low level of contaminant trace-elemen concentration, the accuracy of the final results is a central problem In this field, the research group of Hellin ( F4) published […]

Standartiniai Pranešimai
Gali 14, 2016

10) Rentgeno spindulių spektrometrija – HVC kondensatorius, HV keraminis kondensatorius, skirtas kurti visų rūšių rentgeno aparatus.

10)X-ray Spectrometry–  HVC Capacitor, HV Ceramic Capacitor to build All kinds of X-ray machine. rithm that is based on the comparison of two separately recorded images; one of them is recorded from a phantom sample and the other one is a reconstructed image of the real sample, and the correlation coefficients are calculated. The phantom […]

Standartiniai Pranešimai
Gali 14, 2016

9) Rentgeno spindulių spektrometrija – HVC kondensatorius, HV keraminis kondensatorius, skirtas kurti visų rūšių rentgeno aparatus.

9)X-ray Spectrometry–  HVC Capacitor, HV Ceramic Capacitor to build All kinds of X-ray machine. The properties of the primary X-ray photons, produced deep in the irradiated sample, are modified significantly by the inter- actions (scattering, secondary excitations, etc.) before leaving the specimen. For a better understanding of these processes, Ferna´ ndez et al. (D23 ) […]

Standartiniai Pranešimai
Gali 14, 2016

8) Rentgeno spindulių spektrometrija – HVC kondensatorius, HV keraminis kondensatorius, skirtas kurti visų rūšių rentgeno aparatus.

8)X-ray Spectrometry–  HVC Capacitor, HV Ceramic Capacitor to build All kinds of X-ray machine. An Australian research group (D18 ) published theoretical calculations for the estimation of the contribution of X-ray scattering and second-order fluorescence effects on the absorption measurements, using differently sized apertures to admit varying amounts of the scattered and fluorescence X-ray flux […]

Standartiniai Pranešimai
Gali 13, 2016

7) Rentgeno spindulių spektrometrija – HVC kondensatorius, HV keraminis kondensatorius, skirtas kurti visų rūšių rentgeno aparatus.

7)X-ray Spectrometry–  HVC Capacitor, HV Ceramic Capacitor to build All kinds of X-ray machine. EPMA may require a conventional SEM equipped with an ED X-ray detector for determination of the elementary composition of microsized objects; however, the intensive Bremsstrahlung generated by the exciting electrons in the specimen body increases drastically the minimum detection quantity of […]

Standartiniai Pranešimai
Gali 13, 2016

6) Rentgeno spindulių spektrometrija – HVC kondensatorius, HV keraminis kondensatorius, skirtas kurti visų rūšių rentgeno aparatus.

6)X-ray Spectrometry–  HVC Capacitor, HV Ceramic Capacitor to build All kinds of X-ray machine. INSTRUMENTATION AND X-RAY OPTICS The ultimate goals of focusing X-ray beams are to produce the highest possible flux in the focal point and produce magnified X-ray images. The state-of-the-art focused spots of X-rays are of the order of 50 nm, provided […]

Standartiniai Pranešimai
Gali 13, 2016

5) Rentgeno spindulių spektrometrija – HVC kondensatorius, HV keraminis kondensatorius, skirtas kurti visų rūšių rentgeno aparatus.

5)X-ray Spectrometry–  HVC Capacitor, HV Ceramic Capacitor to build All kinds of X-ray machine. Zhang and co-workers reviewed (B26 ) the development and a test of a new CdZnTe (CZT) pixilated 3-d position-sensitive detector for a wide energy range of X- and ç-rays, coupled to a third-generation ASIC-VAS3.1/TAT3 readout system. The detector bulk is a […]

Standartiniai Pranešimai
Gali 12, 2016

4) Rentgeno spindulių spektrometrija – HVC kondensatorius, HV keraminis kondensatorius, skirtas kurti visų rūšių rentgeno aparatus.

4)X-ray Spectrometry–  HVC Capacitor, HV Ceramic Capacitor to build All kinds of X-ray machine. The energy resolution of the gaseous ED detectors is more and more comparable to that of the semiconductor detectors; in addition, the structure of this low-cost detector is not complex and constructing it is much easier than for high-purity Ge or […]

Standartiniai Pranešimai